Medical External Power Supply UES18LCP4-SPA
Home Wall Plug Medical External Power Supply UES18LCP4-SPA 18W Switching Power Supply Home Healthcare Medical Wall Plug AC External Power Adapter 18 W 90~ 264
140W
80-264VAC
Meets medical & I.T.E. safety
Leakage current ≤100μA
Energy efficiency level VI
≤ 0.15W standby power
5V/9V/12V/15V/20V/28V outputs, up to 140W
Up to 5,000m operating altitude
Meet USB PD3.1&PD3.0&QC4.0+&QC3.0&QC2.0 fast charge agreement
GaN technology
Application place: electrocardiograph, biochemical analyzer, anesthesia monitoring equipment, dental imaging system, small X-ray analyzer, high-frequency electrotherapy device


UES140AZ/UES140BZ-SPC is a versatile 140W AC to DC desktop medical external switching power supply designed for home medical equipment applications, quick charge 3.0 wall charger, providing multiple output options including 5V, 9V, 12V, 15V and 28V, and other voltages (with universal input of 80 ~ 264 Vac) to meet the needs of various medical devices. It meets USB PD3.1 & PD3.0 & QC4.0+ & QC3.0 & QC2.0 fast charging protocols, adopts gallium nitride technology, and complies with the strict safety standards of IEC 60601 1 3.1 version for 2 x MOPP applications and 4th version EMC requirements to ensure Class II power supply 12V operation. This power supply suits electrocardiograph, biochemical analyzer, anesthesia monitoring equipment, dental imaging system, small X-ray analyzer, and high-frequency electrotherapy device.
Safety Standards – IEC60601,EN60601,UL60601
Safety Approvals – CE,CB,TUV-Mark,UL
| Model Number | Power(W) | Input Voltage Range(VAC) | Output Voltage(VDC) | Output Current(A) | Operating Temperature Range(℃) | Safety Standards |
|---|---|---|---|---|---|---|
| UES140AZ/UES140BZ-SPC | 15.0 | 80-264 | 5.0 | 0.01-3.00 | 0 ~ +40 | CE |
| UES140AZ/UES140BZ-SPC | 27.0 | 80-264 | 9.0 | 0.01-3.00 | 0 ~ +40 | CE |
| UES140AZ/UES140BZ-SPC | 36.0 | 80-264 | 12.0 | 0.01-3.00 | 0 ~ +40 | CE |
| UES140AZ/UES140BZ-SPC | 45.0 | 80-264 | 15.0 | 0.01-3.00 | 0 ~ +40 | CE |
| UES140AZ/UES140BZ-SPC | 100.0 | 80-264 | 20.0 | 0.01-5.00 | 0 ~ +40 | CE |
| UES140AZ/UES140BZ-SPC | 140.0 | 80-264 | 28.0 | 0.01-5.00 | 0 ~ +40 | CE |






It is used in patient monitors, ventilators, portable ultrasound machines, dental motors, and mid-size IVD analyzers.
Yes, it can meet IEC 60601-1 standards and is designed for hospital-grade performance.
Yes, it supports a wide output range (5V–28V), making it compatible with multiple devices.
The adapter includes over-voltage, over-current, short-circuit, and over-temperature protection.
Yes, it complies with high-efficiency standards such as DOE Level VI and EU CoC Tier 2.
Absolutely. Output voltage, connector type, label, and casing can be customized for OEM/ODM needs.
It supports universal input: 90–264V AC, 47–63Hz.
Yes, it can power dental handpieces, LED curing lights, and certified RF/laser beauty systems.
It typically uses natural air cooling with high efficiency and low heat output.
Yes, it is designed for continuous operation with stable performance and long lifespan.

Home Wall Plug Medical External Power Supply UES18LCP4-SPA 18W Switching Power Supply Home Healthcare Medical Wall Plug AC External Power Adapter 18 W 90~ 264

Home Medical External Desktop Power Supply UES180DZ-SPA Series 180W AC-DC Desktop Medical External Power Supply 56V Switching Power Adapter 180 W 90 ~ 264 Vac

Home Wall Plug Medical External Power Supply UES36WZ1-SPA 12 Volt DC Plug Adapter Wall Plug Medical External Power Supply For Home Devices 36 W 90~

Why Do Many Medical Devices Fail IEC 60601 Certification Even with an Isolated Power Supply? Many medical device manufacturers assume that using an isolated AC-DC

Growing demand for portable medical devices, AI-assisted diagnostic equipment, laboratory instruments, and USB-C powered healthcare systems is driving the need for higher-power medical adapters that

Thermal Failure Mechanisms, IEC 60601 Risks, and Engineering Solutions Overheating is one of the most common causes of medical power supply failure. In medical devices, excessive

How to Identify, Diagnose, and Reduce EMI Problems in Medical Devices Electromagnetic interference (EMI) is one of the most common and difficult problems in medical

Why Medical Devices Fail EMC Certification and How to Fix It Electromagnetic compatibility (EMC) is one of the most challenging parts of IEC 60601 certification

IEC 60601 Design Challenges, Root Causes, and Engineering Solutions Leakage current is one of the most critical safety parameters in medical electrical equipment design. For
For additional assistance, please complete the form below, and an associate will be in touch with you shortly.