UES18LCP4-SPA
The UES18LCP4-SPA is a wall-plug power supply for compact medical equipment, with output configurations for higher-current 5V electronics and small pump-driven devices.

| Model Number | Power(W) | Input Voltage Range(VAC) | Output Voltage(VDC) | Output Current(A) | Operating Temperature Range(°C) | Safety Standards |
| UES18LCP4-XXXYYYSPA | 18 | 80–264 | 5.0–6.0 | 0.01–3.00 | 0–45 | CB, UL, TÜV Rheinland/Mark |
| UES18LCP4-XXXYYYSPA | 14 | 80–264 | 6.1–7.0 | 0.01–2.00 | 0–45 | CB, UL, TÜV Rheinland/Mark |
| UES18LCP4-XXXYYYSPA | 16 | 80–264 | 7.1–8.0 | 0.01–2.00 | 0–45 | CB, UL, TÜV Rheinland/Mark |
| UES18LCP4-XXXYYYSPA | 18 | 80–264 | 8.1–9.0 | 0.01–2.00 | 0–45 | CB, UL, TÜV Rheinland/Mark |
| UES18LCP4-XXXYYYSPA | 18 | 80–264 | 9.1–10.0 | 0.01–1.80 | 0–45 | CB, UL, TÜV Rheinland/Mark |
| UES18LCP4-XXXYYYSPA | 18 | 80–264 | 10.1–11.0 | 0.01–1.65 | 0–45 | CB, UL, TÜV Rheinland/Mark |
| UES18LCP4-XXXYYYSPA | 18 | 80–264 | 11.1–12.0 | 0.01–1.50 | 0–45 | CB, UL, TÜV Rheinland/Mark |
| UES18LCP4-XXXYYYSPA | 18 | 80–264 | 12.1–13.0 | 0.01–1.40 | 0–45 | CB, UL, TÜV Rheinland/Mark |
| UES18LCP4-XXXYYYSPA | 18 | 80–264 | 13.1–14.0 | 0.01–1.30 | 0–45 | CB, UL, TÜV Rheinland/Mark |
| UES18LCP4-XXXYYYSPA | 18 | 80–264 | 14.1–15.0 | 0.01–1.20 | 0–45 | CB, UL, TÜV Rheinland/Mark |
| UES18LCP4-XXXYYYSPA | 18 | 80–264 | 15.1–16.0 | 0.01–1.13 | 0–45 | CB, UL, TÜV Rheinland/Mark |
| UES18LCP4-XXXYYYSPA | 18 | 80–264 | 16.1–17.0 | 0.01–1.10 | 0–45 | CB, UL, TÜV Rheinland/Mark |
| UES18LCP4-XXXYYYSPA | 18 | 80–264 | 17.1–18.0 | 0.01–1.05 | 0–45 | CB, UL, TÜV Rheinland/Mark |
| UES18LCP4-XXXYYYSPA | 18 | 80–264 | 18.1–19.0 | 0.01–0.95 | 0–45 | CB, UL, TÜV Rheinland/Mark |
| UES18LCP4-XXXYYYSPA | 18 | 80–264 | 19.1–20.0 | 0.01–0.90 | 0–45 | CB, UL, TÜV Rheinland/Mark |
| UES18LCP4-XXXYYYSPA | 18 | 80–264 | 20.1–21.0 | 0.01–0.86 | 0–45 | CB, UL, TÜV Rheinland/Mark |
| UES18LCP4-XXXYYYSPA | 18 | 80–264 | 21.1–22.0 | 0.01–0.82 | 0–45 | CB, UL, TÜV Rheinland/Mark |
| UES18LCP4-XXXYYYSPA | 18 | 80–264 | 22.1–23.0 | 0.01–0.80 | 0–45 | CB, UL, TÜV Rheinland/Mark |
| UES18LCP4-XXXYYYSPA | 18 | 80–264 | 23.1–24.0 | 0.01–0.75 | 0–45 | CB, UL, TÜV Rheinland/Mark |

| Input Characteristic | Specification |
| Input Voltage Range | 80–264VAC |
| Frequency Range | 47–63Hz |
| Input Current | 0.5A at 90VAC |
| Inrush Current | 70A max. at 240VAC, cold start |
| Touch Leakage Current | ≤100μA at 264VAC |
| Characteristic | Specification |
| Operating Temperature | 0°C to +45°C |
| Storage Temperature | −20°C to +60°C |
| Operating Humidity | 10–90% RH, non-condensing |
| Storage Humidity | 5–90% RH |
| Operating Altitude | Up to 5,000m |
| Enclosure Rating | IP22 |
| Construction | Class II |
| Standby Power | ≤0.075W |
| Average Efficiency | 81.84–85.37%, depending on output group |
| Energy Efficiency | Level VI series claim; the 5.0–6.0V group carries the Level V-only note |
| MTBF | >100,000 hours, Telcordia SR-332 at 25°C |
| Protection Function | Specification |
| Overload | 120–150% of rated output power; automatic recovery |
| Overvoltage | 120–150% of rated output voltage; input reset required |
| Short Circuit | Trip and restart, hiccup mode |
IEC60601-1
View CertificateEN60601-1
View Certificate60601-1
View Certificate| EMC Item | Medical Reference / Listed Level |
| Conducted Emissions | IEC/EN 60601-1-2, CISPR 11 |
| Radiated Emissions | IEC/EN 60601-1-2, CISPR 11 |
| Harmonic Currents | EN 61000-3-2, Class A |
| Voltage Flicker | EN 61000-3-3 |
| Immunity | IEC/EN 60601-1-2 |
| ESD | IEC 61000-4-2; ±15kV air, ±8kV contact |
| Radiated Immunity | IEC 61000-4-3; 10V/m and 3V/m, 80–2700MHz |
| EFT / Burst | IEC 61000-4-4; ±2kV AC port, ±1kV signal ports |
| Surge | IEC 61000-4-5; ±2kV line-to-line, differential mode |
| Conducted Immunity | IEC 61000-4-6; 3Vrms and 6Vrms, 0.15–80MHz |
| Magnetic Field | IEC 61000-4-8; 30A/m |
| Voltage Dips & Interruptions | IEC 61000-4-11; 0%, 70%, 0% of UT |
This series is a selection option for small, externally powered medical devices. Its output choices cover requirements such as 5V electronics, 9V pumps and 12V control systems. The equipment’s input rating determines the configuration; the application name alone doesn’t establish compatibility.




These articles help with three decisions around this adapter: how to interpret output-current ratings, what the medical isolation terminology means, and what changes when equipment is intended for home use.
An explanation of current capacity, load demand and replacement selection. Although the examples compare 1A and 2A supplies, the same distinction helps when deciding whether a 3A output suits a lower-current device.
A guide to the isolation barrier between mains power and the medical device. Read it when comparing supplies or discussing how the adapter contributes to the equipment’s electrical safety design.
An introduction to electrical safety, environmental conditions and EMC considerations for equipment used by patients and caregivers at home. Useful when preparing a product requirement rather than selecting by voltage and wattage alone.
Our engineering team provides comprehensive support for this power supply series. Whether you need standard models, custom DC output specifications, or specific medical compliance assistance, we ensure your requirements are met with precision and speed.
✔ 2 MOPP & IEC 60601-1 Certification Support
✔ Custom DC Connectors & Cable Options
✔ Free Engineering Samples for Evaluation
✔ Detailed Technical Response within 24h