Medical Power Supply UES100B-SPCZ
Home Medical Power Supply UES100B-SPCZ/UES100C-SPCZ Desktop homecare 15v 20v switching AC DC power supply Medical&l.T.E.safety approvals 2 MOPP input to output isolation Leakage currents ≤100uA
90W
80-264VAC
Meets medical & I.T.E. safety
Leakage current ≤100μA
DOE level VI
≤ 0.21W standby power
11V to 54V outputs, up to 140W
Up to 5,000m operating altitude
4 types of AC inlet
Application place: oxygen concentrator, electric treatment chair, infant incubator, electrochemical analyzer, laser therapy device, medical air compressor


Safety Standards – IEC60601,EN60601,UL60601
Safety Approvals – CE, CB ,TUV-Mark ,UL
| Model Number | Power(W) | Input Voltage Range(VDC) | Output Voltage(VDC) | Output Current(A) | Operating Temperature Range(℃) | Safety Standards |
|---|---|---|---|---|---|---|
| UES90C-SPAZ | 77.0 | 80-264 | 11.0 | 0.01-7.00 | 0 ~ +40 | CB, CCC, CE, NRTL |
| UES90C-SPAZ | 84.0 | 80-264 | 12.0 | 0.01-7.00 | 0 ~ +40 | CB, CCC, CE, NRTL |
| UES90C-SPAZ | 90.0 | 80-264 | 15.0 | 0.01-6.00 | 0 ~ +40 | CB, CCC, CE, NRTL |
| UES90C-SPAZ | 90.0 | 80-264 | 17.0 | 0.01-5.29 | 0 ~ +40 | CB, CCC, CE, NRTL |
| UES90C-SPAZ | 90.0 | 80-264 | 19.0 | 0.01-4.74 | 0 ~ +40 | CB, CCC, CE, NRTL |
| UES90C-SPAZ | 90.0 | 80-264 | 22.0 | 0.01-4.09 | 0 ~ +40 | CB, CCC, CE, NRTL |
| UES90C-SPAZ | 90.0 | 80-264 | 24.0 | 0.01-3.75 | 0 ~ +40 | CB, CCC, CE, NRTL |
| UES90C-SPAZ | 90.0 | 80-264 | 26.0 | 0.01-3.46 | 0 ~ +40 | CB, CCC, CE, NRTL |
| UES90C-SPAZ | 90.0 | 80-264 | 30.0 | 0.01-3.00 | 0 ~ +40 | CB, CCC, CE, NRTL |
| UES90C-SPAZ | 90.0 | 80-264 | 33.0 | 0.01-2.73 | 0 ~ +40 | CB, CCC, CE, NRTL |
| UES90C-SPAZ | 90.0 | 80-264 | 36.0 | 0.01-2.50 | 0 ~ +40 | CB, CCC, CE, NRTL |
| UES90C-SPAZ | 90.0 | 80-264 | 39.0 | 0.01-2.31 | 0 ~ +40 | CB, CCC, CE, NRTL |
| UES90C-SPAZ | 90.0 | 80-264 | 43.0 | 0.01-2.09 | 0 ~ +40 | CB, CCC, CE, NRTL |
| UES90C-SPAZ | 90.0 | 80-264 | 46.0 | 0.01-1.95 | 0 ~ +40 | CB, CCC, CE, NRTL |
| UES90C-SPAZ | 90.0 | 80-264 | 48.0 | 0.01-1.88 | 0 ~ +40 | CB, CCC, CE, NRTL |
| UES90C-SPAZ | 90.0 | 80-264 | 52.0 | 0.01-1.73 | 0 ~ +40 | CB, CCC, CE, NRTL |
| UES90C-SPAZ | 90.0 | 80-264 | 54.0 | 0.01-1.67 | 0 ~ +40 | CB, CCC, CE, NRTL |






It supports a wide output range from 11V to 54V.
The adapter delivers up to 90 watts of continuous power.
It's ideal for ultrasound systems, CPAP/BiPAP machines, centrifuges, infusion devices, and medical imaging units.
Yes, it can be built to meet IEC 60601-1 and other medical safety standards.
Yes, it supports up to 54V for devices like laser therapy systems and medical carts.
Absolutely. It includes protections for over-voltage, over-current, short-circuit, and overheating.
Yes, it features a fanless design for silent and reliable operation.
Yes, its compact and external design makes it ideal for portable equipment.
Yes, it accepts 100–240V AC input, suitable for global use.
Yes, we provide multiple DC connectors and cable customizations.

Home Medical Power Supply UES100B-SPCZ/UES100C-SPCZ Desktop homecare 15v 20v switching AC DC power supply Medical&l.T.E.safety approvals 2 MOPP input to output isolation Leakage currents ≤100uA

Home Medical Power Supply UES100LCP2-SPC 12 volt regulated power supply, wall plug external switching power supply Meets communication and medical safety certification 2 MOPP isolation

Home Medical Switching Power Supply UES80D-SPA 80W Desktop External Hospital Grade AC-DC Switching Power Supply 80 W 90 ~ 264 Vac input (wide) 0 to

Why Do Many Medical Devices Fail IEC 60601 Certification Even with an Isolated Power Supply? Many medical device manufacturers assume that using an isolated AC-DC

Growing demand for portable medical devices, AI-assisted diagnostic equipment, laboratory instruments, and USB-C powered healthcare systems is driving the need for higher-power medical adapters that

Thermal Failure Mechanisms, IEC 60601 Risks, and Engineering Solutions Overheating is one of the most common causes of medical power supply failure. In medical devices, excessive

How to Identify, Diagnose, and Reduce EMI Problems in Medical Devices Electromagnetic interference (EMI) is one of the most common and difficult problems in medical

Why Medical Devices Fail EMC Certification and How to Fix It Electromagnetic compatibility (EMC) is one of the most challenging parts of IEC 60601 certification

IEC 60601 Design Challenges, Root Causes, and Engineering Solutions Leakage current is one of the most critical safety parameters in medical electrical equipment design. For
For additional assistance, please complete the form below, and an associate will be in touch with you shortly.