
Medical External Power Supply UES18LCP4-SPA
Home Wall Plug Medical External Power Supply UES18LCP4-SPA 18W Switching Power Supply Home Healthcare Medical Wall Plug AC External Power Adapter 18 W 90~ 264
65 W
90~ 264 Vac input
0°C to +40°C temperature range
No-load power consumption < 0.15 W
2 MOPP input-to-output isolation
Application place: ultrasonic nebulizer, electronic endoscope, home ventilator, body composition analyzer, physiotherapy equipment, ophthalmology optometry machine


The UES65B1-SPA is a USB C PD Charger 65W AC to DC wall plug external medical power adapter 12V designed for home healthcare applications, It offers multiple output options, including 12V, 15V, 20V, and 24V, among other voltages (coming with a universal input of 90 ~ 264 Vac), This power supply features four AC input ports and adheres to the stringent safety standards of IEC 60601-1 3.1 Edition for 2 x MOPP applications, as well as the 4th Edition EMC requirements, ensuring class II power supply operation, USB type c power adapter, this 65W power supply provides a wide selection of AC plugs and DC connectors to ensure compatibility with your specific devices and equipment, and small size suitable for ultrasonic nebulizer, electronic endoscope, home ventilator, body composition analyzer, physiotherapy equipment, ophthalmology optometry machine.
Safety Standards – IEC60601,EN60601
Safety Approvals – CB, NRTL, PSE, TUV-Mark
| Model Number | Power(W) | Input Voltage Range(VDC) | Output Voltage(VDC) | Output Current(A) | Operating Temperature Range(℃) | Safety Standards |
|---|---|---|---|---|---|---|
| UES65B1-SPA | 60.0 | 90-264 | 11.0-12.0 | 0.01-5.00 | 0 ~ +40 | CB, NRTL, PSE, TUV-Mark |
| UES65B1-SPA | 60.0 | 90-264 | 12.1-13.0 | 0.01-4.61 | 0 ~ +40 | CB, NRTL, PSE, TUV-Mark |
| UES65B1-SPA | 60.0 | 90-264 | 13.1-14.0 | 0.01-4.28 | 0 ~ +40 | CB, NRTL, PSE, TUV-Mark |
| UES65B1-SPA | 60.0 | 90-264 | 14.1-15.0 | 0.01-4.00 | 0 ~ +40 | CB, NRTL, PSE, TUV-Mark |
| UES65B1-SPA | 60.0 | 90-264 | 15.1-16.0 | 0.01-3.75 | 0 ~ +40 | CB, NRTL, PSE, TUV-Mark |
| UES65B1-SPA | 60.0 | 90-264 | 16.1-17.0 | 0.01-3.52 | 0 ~ +40 | CB, NRTL, PSE, TUV-Mark |
| UES65B1-SPA | 60.0 | 90-264 | 17.1-18.0 | 0.01-3.33 | 0 ~ +40 | CB, NRTL, PSE, TUV-Mark |
| UES65B1-SPA | 65.0 | 90-264 | 19.0 | 0.01-3.42 | 0 ~ +40 | CB, NRTL, PSE, TUV-Mark |
| UES65B1-SPA | 65.0 | 90-264 | 19.1-20.0 | 0.01-3.25 | 0 ~ +40 | CB, NRTL, PSE, TUV-Mark |
| UES65B1-SPA | 65.0 | 90-264 | 20.1-21.0 | 0.01-3.09 | 0 ~ +40 | CB, NRTL, PSE, TUV-Mark |
| UES65B1-SPA | 65.0 | 90-264 | 21.1-22.0 | 0.01-2.95 | 0 ~ +40 | CB, NRTL, PSE, TUV-Mark |
| UES65B1-SPA | 65.0 | 90-264 | 22.1-23.0 | 0.01-2.82 | 0 ~ +40 | CB, NRTL, PSE, TUV-Mark |
| UES65B1-SPA | 65.0 | 90-264 | 23.1-24.0 | 0.01-2.71 | 0 ~ +40 | CB, NRTL, PSE, TUV-Mark |






It's suitable for medical devices, industrial controls, POS systems, and communication equipment.
Devices like patient monitors, portable ultrasounds, network devices, and test instruments.
Yes, models can be designed to meet IEC 60601-1 and 2xMOPP standards.
Yes, it accepts 100–240V AC input for worldwide use.
Over-voltage, over-current, short-circuit, and thermal protection.
It reduces internal heat, improves safety, and is easier to service or replace.
Yes, we support custom DC plugs, cable lengths, and labels.
Yes, it's compact and ideal for mobile or handheld devices.
It provides sufficient power for mid-range devices without overheating.
Yes, it meets DOE Level VI or EU CoC Tier 2 efficiency standards (on request).

Home Wall Plug Medical External Power Supply UES18LCP4-SPA 18W Switching Power Supply Home Healthcare Medical Wall Plug AC External Power Adapter 18 W 90~ 264

Home Medical External Desktop Power Supply UES180DZ-SPA Series 180W AC-DC Desktop Medical External Power Supply 56V Switching Power Adapter 180 W 90 ~ 264 Vac

Home Medical External Power Supply UES65-SPAZ Series 65W 9V Desktop Medical External AC DC Power Supply with different AC inlet input 65 W 85 ~

Why Do Many Medical Devices Fail IEC 60601 Certification Even with an Isolated Power Supply? Many medical device manufacturers assume that using an isolated AC-DC

Growing demand for portable medical devices, AI-assisted diagnostic equipment, laboratory instruments, and USB-C powered healthcare systems is driving the need for higher-power medical adapters that

Thermal Failure Mechanisms, IEC 60601 Risks, and Engineering Solutions Overheating is one of the most common causes of medical power supply failure. In medical devices, excessive

How to Identify, Diagnose, and Reduce EMI Problems in Medical Devices Electromagnetic interference (EMI) is one of the most common and difficult problems in medical

Why Medical Devices Fail EMC Certification and How to Fix It Electromagnetic compatibility (EMC) is one of the most challenging parts of IEC 60601 certification

IEC 60601 Design Challenges, Root Causes, and Engineering Solutions Leakage current is one of the most critical safety parameters in medical electrical equipment design. For
For additional assistance, please complete the form below, and an associate will be in touch with you shortly.
