Quankang | Professional Medical Power Supply Manufacturer

UES15D-SPA | 5V-24V 15W Medical Open Frame Power Supply

UES15D-SPA Series

The series combines a 15W power rating with 2 MOPP input-to-output isolation and touch leakage current ≤100μA.

  • Seven fixed outputs: 5V, 6V, 9V, 12V, 15V, 18V and 24V
  • 54.0 × 36.8 × 20.3mm body, weighing 48g
  • PCB-mount pins for installation inside the equipment
  • 2 MOPP input-to-output isolation and 4,000VAC dielectric withstand voltage
  • Touch leakage current ≤100μA at 264VAC
  • Standby power ≤0.25W
  • 85–265VAC input, with an operating temperature range of −25°C to +65°C
UES15D-SPA 5V-24V 15W medical open frame power supply

Models & Ratings

For a 12V design, the UES15D-SPA offers up to 1.25A. Choose the 24V version and the available current drops to 0.62A. Both belong to the same 15W series, so the voltage alone is only half the selection.

There are seven fixed-output versions in the table below, including 6V, 9V, 15V and 18V alongside the more familiar 5V, 12V and 24V options. Each is a separate version. Tell us which output you need when requesting a quotation; UES15D-XXXYYYSPA is the catalog’s model-code format, not the complete code for a specific output.
Model NumberPower(W)Input Voltage Range(VAC)Output Voltage(VDC)Output Current(A)Operating Temperature Range(°C)Safety Standards
UES15D-XXXYYYSPA1585–26550.01–3.00−25 to +65CB, UL, CE, TÜV Mark
UES15D-XXXYYYSPA1585–26560.01–2.50−25 to +65CB, UL, CE, TÜV Mark
UES15D-XXXYYYSPA1585–26590.01–1.67−25 to +65CB, UL, CE, TÜV Mark
UES15D-XXXYYYSPA1585–265120.01–1.25−25 to +65CB, UL, CE, TÜV Mark
UES15D-XXXYYYSPA1585–265150.01–1.00−25 to +65CB, UL, CE, TÜV Mark
UES15D-XXXYYYSPA1585–265180.01–0.83−25 to +65CB, UL, CE, TÜV Mark
UES15D-XXXYYYSPA1585–265240.01–0.62−25 to +65CB, UL, CE, TÜV Mark

Mechanical Details

The UES15D-SPA brings the power supply inside your device, with four pins connecting it directly to the PCB. The body measures 54.0 × 36.8 × 20.3mm and weighs 48g.

Two pins take the AC input, and two carry the DC output. There is no separate DC cable or output plug in this configuration. The drawing below shows the pin positions and dimensions you need for the board layout.
UES15D SPA Mechanical details

Input Specifications

One UES15D-SPA input platform covers 85–265VAC, 47–63Hz. This includes common 100V, 120V, 230V and 240V mains systems within the stated input range.

Pay attention to the cold-start inrush when choosing the equipment’s input components. The listed 0.5A input current and 100A maximum inrush current describe different conditions; they should not be used interchangeably.
Input CharacteristicSpecification
Input Voltage Range85–265VAC
Frequency Range47–63Hz
Input Current0.5A at 100VAC
Inrush Current100A max at 240VAC, cold start
Standby Power≤0.25W

If your product has its own mains switch, fuse or input filter, include those components in the input design review.

Environmental & General

The air around the power supply can be warmer than the room outside your device. This is worth checking on an enclosed prototype, particularly if the UES15D-SPA sits close to a motor, display or another source of heat.

The catalog gives an operating range of −25°C to +65°C, but it does not show a load-versus-temperature curve on these pages. If your enclosure runs near the upper limit, confirm the permitted load for that temperature before settling on the design.
Operating Temperature−25°C to +65°C
Storage Temperature−25°C to +85°C
Operating Humidity10–90% RH, non-condensing
Storage Humidity10–90% RH
Operating AltitudeUp to 5,000m
MTBF>100,000 hours, Telcordia SR-332 at 25°C

The listed >100,000-hour MTBF is calculated using Telcordia SR-332 at 25°C. It is a reference for reliability assessment—not a promise that an individual supply will run for that many hours.

Protection

The UES15D-SPA responds to overload, overvoltage and short-circuit conditions. The way it returns to operation depends on which protection has operated.
Overload110–180% of rated output power; automatic recovery
OvervoltageCatalog specifies 150% max of output voltage; input reset required
Short CircuitOutput trips and attempts to restart in hiccup mode
For overloads and short circuits, first remove the cause of the fault. Overvoltage protection requires the AC input to be reset.

The overload threshold is not extra output capacity. A motor or another load with a short starting surge still needs to be checked against the supply’s permitted operating conditions.

Safety Approvals

The UES15D-SPA has 2 MOPP isolation between the AC input and DC output. The catalog specifies 4,000VAC input-to-output dielectric withstand voltage and touch leakage current ≤100μA at 264VAC.

For your compliance review, ask for the documents covering the exact output version you plan to order. The catalog lists the following marks and standards.
CB

IEC60601-1

View Certificate
TÜV

EN60601-1

View Certificate

EMC

The catalog covers both medical and ITE emissions and immunity references. For a medical equipment project, the medical column below is the starting point for reviewing the applicable EMC documents.  
ItemMedicalITE
Conducted EmissionsIEC/EN 60601-1-2; CISPR 11EN 55032; CISPR 32
Radiated EmissionsIEC/EN 60601-1-2; CISPR 11EN 55032; CISPR 32
Harmonic CurrentsEN 61000-3-2, Class AEN 61000-3-2, Class A
Voltage FlickerEN 61000-3-3EN 61000-3-3
ImmunityIEC/EN 60601-1-2EN 55035; CISPR 35
The listed immunity tests include ESD, radiated RF, electrical fast transients, surge, conducted RF, magnetic fields, and voltage dips and interruptions.

Test the supply in the finished equipment configuration. PCB routing, mains wiring, the enclosure and connected cables can change the result from that of the power supply alone.

Common Applications

This 15W medical open frame power supply is intended for installation inside equipment. The applications below are starting points for OEM selection, with the output chosen to suit the complete device load.

For equipment with a motor or rechargeable battery, include starting demand and charging power—not just the consumption during normal operation.
Syringe Pumps
Syringe Pumps
Compact Urinalysis Analyzers
Compact Urinalysis Analyzers
Dental Curing Light Bases
Dental Curing Light Bases
Infusion Pump power supply
Infusion Pump

Frequently Asked Questions

Is the UES15D-SPA suitable for my device?

First, what output voltage and current does your device need? Do you need any certifications, and which ones are required for your project?

If you already have a power supply, you can send us a photo of its label along with your device’s power requirements. That gives us a starting point for checking the output and certification requirements. Since the UES15D-SPA mounts inside the equipment, we’ll also need to know how much installation space you have.

With those details, we can check whether this model fits or whether another model would be a better choice.

Possibly. Let’s compare the drawings before you make any changes.

The UES15D-SPA has four pins, with different spacing on the AC and DC sides. Matching the output is the first step; the pin positions and assignments also need to match your board. A photo of the existing supply is useful, but a drawing will give us a much clearer answer.

With a pump, we’d look at the starting current as well as the current once it is running. The two figures can be quite different.

What pump are you using? Please send us its model number or a photo of the label. We may also need the starting-current figure, since that is not always shown on the label.

Yes. Tell us the voltage and current needed for each product, and we can check which versions match.

For example, one product might need 6V at 2A, while another needs 9V at 1.5A. Both fall within the corresponding versions’ listed current ratings. They would be two different units, though—you cannot change one unit between those outputs.

The body is 54.0 × 36.8 × 20.3mm. Do you have a layout drawing showing where you want to put it? A sketch with dimensions is also useful.

We’ll look at the pin locations and the space around the supply as well as the body size. Please show any nearby components too, particularly anything that gets warm during use.

How much current does it use while charging? That is the figure we need alongside the device’s operating current.

If your existing test only covers the device running with a fully charged battery, it may not show the highest load. Try to include the condition where the device is working and the battery is charging. The battery also needs its own charging circuit; that function is not built into the UES15D-SPA.

Related Models

Need more current or a different output range? These series offer other power levels and installation formats. Check their drawings and ratings before selecting one for the same equipment.
UES240-XXXYYYSPA-OP

Medical Open Frame Power Supply UES240-XXXYYYSPA-OP

Medical Open Frame Power Supply UES150-540277SPA1-OP

UES150-SPA-OP 12V-48V 150W Medical Open Frame Power Supply

Medical Open Frame Power Supply UES150-XXXYYYSPA-OP

320w open frame power supply

Medical Open Frame Power Supply UES320-XXXYYYSPA-OP

Related Resources

Still checking whether this supply fits your project? These articles explain the medical isolation terms, installation details and safety documents you may need to review before making a choice.

What does 2 x MOPP mean for a medical power supply?

You’ll find 2 MOPP in the UES15D-SPA specifications. What does it mean for your device? This article looks at patient protection and the insulation requirements behind the term, giving you some background before reviewing the supply with your compliance team.

How to Install Open Frame AC-DC Power Supplies

Finding room for the power supply is one part of the installation. Wiring, cooling and electrical clearances need space too. This guide walks through those considerations and provides a checklist to review before closing the equipment enclosure.

12V 1A vs 12V 2A Adapter: Which One Should You Choose?

Two supplies can have the same voltage and very different current ratings. If you’re comparing the UES15D-SPA’s 12V version with another supply, this article explains what those current figures mean, why a higher rating does not force extra current into the device, and where starting demand matters.

Request Technical Support & Pricing

Our engineering team provides comprehensive support for this power supply series. Whether you need standard models, custom DC output specifications, or specific medical compliance assistance, we ensure your requirements are met with precision and speed.

✔ 2 MOPP & IEC 60601-1 Certification Support

✔ Custom DC Connectors & Cable Options

✔ Free Engineering Samples for Evaluation

✔ Detailed Technical Response within 24h

Request a Free Quote

Send us a message if you have any questions or request a quote. We will be back to you ASAP!