- UES240E-SPCZ / UES240F-SPCZ | 5V–48V 240W Medical Desktop Power Adapter
UES240E-SPCZ / UES240F-SPCZ | 5V–48V 240W Medical Desktop Power Adapter
UES240E-SPCZ / UES240F-SPCZ
Medical USB-C PD power up to 240W, with higher-voltage profiles for equipment designed to use 36V or 48V inputs.
- 180W at 36V; 240W at 48V
- USB PD 3.2, AVS and PPS support
- Type-C socket or fixed output lead
- 2 MOPP input-to-output isolation
- Medical and home healthcare approval references

Models & Ratings
Start with the input your equipment needs. A 48V design can use the listed 240W profile; a 36V design has up to 180W available. At 20V, the limit is 100W.
E and F share these output ratings. The choice between them concerns the output connection, so you can settle the electrical requirement first and then choose the cable arrangement. The table below shows the fixed profiles. AVS and PPS requirements need checking separately because their ranges are not given in the supplied specification.
| Model Number | Power(W) | Input Voltage Range(VAC) | Output Voltage(VDC) | Output Current(A) | Operating Temperature Range(°C) | Safety Standards |
| UES240E-SPCZ / UES240F-SPCZ | 15 | 90–264 / 80–264* | 5 | 0.01–3.00 | −10 to +40 | CB, UL, TÜV-SÜD/Mark |
| UES240E-SPCZ / UES240F-SPCZ | 27 | 90–264 / 80–264* | 9 | 0.01–3.00 | −10 to +40 | CB, UL, TÜV-SÜD/Mark |
| UES240E-SPCZ / UES240F-SPCZ | 36 | 90–264 / 80–264* | 12 | 0.01–3.00 | −10 to +40 | CB, UL, TÜV-SÜD/Mark |
| UES240E-SPCZ / UES240F-SPCZ | 45 | 90–264 / 80–264* | 15 | 0.01–3.00 | −10 to +40 | CB, UL, TÜV-SÜD/Mark |
| UES240E-SPCZ / UES240F-SPCZ | 100 | 90–264 / 80–264* | 20 | 0.01–5.00 | −10 to +40 | CB, UL, TÜV-SÜD/Mark |
| UES240E-SPCZ / UES240F-SPCZ | 140 | 90–264 / 80–264* | 28 | 0.01–5.00 | −10 to +40 | CB, UL, TÜV-SÜD/Mark |
| UES240E-SPCZ / UES240F-SPCZ | 180 | 90–264 / 80–264* | 36 | 0.01–5.00 | −10 to +40 | CB, UL, TÜV-SÜD/Mark |
| UES240E-SPCZ / UES240F-SPCZ | 240 | 90–264 / 80–264* | 48 | 0.01–5.00 | −10 to +40 | CB, UL, TÜV-SÜD/Mark |
Mechanical Details

Input Specifications
| Input Characteristic | Specification |
| Input voltage — Class I | 90–264VAC |
| Input voltage — Class II | 80–264VAC |
| Frequency range | 47–63Hz |
| Input current | 4.0A maximum at 80VAC |
| Standby power | ≤0.15W |
| AC Inlet Options |
| C8 / Polarized C8 — Class II; replace Z with 1 |
| C6 — Class I; replace Z with 2 |
| C14 — Class I; replace Z with 3 |
| C18 — Class II; replace Z with 4 |
Environmental & General
| Characteristic | Specification |
| Operating temperature | −10°C to +40°C |
| Storage temperature | −20°C to +80°C |
| Operating humidity | 10–90% RH, non-condensing |
| Storage humidity | 5–90% RH |
| Operating altitude | Up to 5,000m |
| Enclosure rating | IP42 |
| Weight | 650g ±15g |
| Energy efficiency | Level VII, as listed in the specification |
| MTBF | >100,000 hours, Telcordia SR-332 at 25°C |
| Output Profile | Average Efficiency |
| 5V | 82.00% |
| 9V | 87.30% |
| 12V | 88.30% |
| 15V | 88.90% |
| 20V | 89.50% |
| 28V | 90.00% |
| 36V | 91.00% |
| 48V | 91.50% |
Protection
| Protection Function | Specification | Recovery |
| Overload | 105–140% of rated output power | Automatic recovery |
| Overvoltage | 110–130% of rated output voltage | AC input reset required |
| Short circuit | Trip and restart, hiccup mode | Restart attempts while the fault remains |
Safety Approvals
IEC60601-1
View CertificateEN60601-1
View Certificate60601-1
View CertificateEMC
| Item | Medical Specification |
| Conducted emissions | IEC/EN 60601-1-2, CISPR 11 |
| Radiated emissions | IEC/EN 60601-1-2, CISPR 11 |
| Harmonic currents | EN 61000-3-2, Class A |
| Voltage flicker | EN 61000-3-3 |
| Immunity | IEC/EN 60601-1-2 |
| Immunity Test | Standard | Specified Level |
| ESD | IEC 61000-4-2 | ±15kV air, ±8kV contact |
| Radiated immunity | IEC 61000-4-3 | 3V/m |
| EFT/Burst | IEC 61000-4-4 | ±2kV AC port, ±1kV signal ports |
| Surge | IEC 61000-4-5 | ±2kV line-to-neutral; ±4kV line/neutral-to-ground |
| Conducted immunity | IEC 61000-4-6 | 3Vrms, 6Vrms; 0.15–80MHz |
| Magnetic field | IEC 61000-4-8 | 30A/m |
| Dips and interruptions | IEC 61000-4-11 | 0%, 70%, 0% of UT |
Common Applications




Frequently Asked Questions
We’re moving our medical equipment to USB-C. What do you need to check before recommending this model?
Our equipment resets when the PD voltage changes. Would a higher-wattage adapter help?
Is that 240W from one output?
Our equipment needs 200W. Would you recommend this one?
We have a 100W USB-C cable already. Can we use it?
E or F—which would you choose for our equipment?
Related Models
Related Resources
Medical grade USB-C power supply
What does 2 x MOPP mean for a medical power supply?
Power Supply Derating: How to Calculate Output Limits for Temperature, Altitude, and Cooling
Request Technical Support & Pricing
Our engineering team provides comprehensive support for this power supply series. Whether you need standard models, custom DC output specifications, or specific medical compliance assistance, we ensure your requirements are met with precision and speed.
✔ 2 MOPP & IEC 60601-1 Certification Support
✔ Custom DC Connectors & Cable Options
✔ Free Engineering Samples for Evaluation
✔ Detailed Technical Response within 24h