UES60D1-200300SPC
60W USB-C PD desktop power adapter designed for medical and portable equipment applications. Featuring compact desktop construction, 2 x MOPP isolation and medical safety approvals for equipment requiring higher power and patient protection.

UES60D1-200300SPC is a 60W USB-C PD desktop power adapter supporting multiple output profiles from 5V to 20V. The series provides 3A output capability across all voltage settings, including 20V/3A for devices requiring up to 60W input power.
The USB Type-C interface supports PD3.0 fast charging communication, allowing compatible equipment to select the required voltage profile according to its power demand.
| Model Number | Power(W) | Input Voltage Range(VAC) | Output Voltage(VDC) | Output Current(A) | Operating Temperature Range(℃) | Safety Standards |
| UES60D1-200300SPC | 15 | 90-264 | 5 | 0.01-3.00 | 0~+40 | CB, CCC, CE, cULus, FCC, NRTL, PSE, RCM, TUV-GS, TUV-Mark |
| UES60D1-200300SPC | 27 | 90-264 | 9 | 0.01-3.00 | 0~+40 | CB, CCC, CE, cULus, FCC, NRTL, PSE, RCM, TUV-GS, TUV-Mark |
| UES60D1-200300SPC | 36 | 90-264 | 12 | 0.01-3.00 | 0~+40 | CB, CCC, CE, cULus, FCC, NRTL, PSE, RCM, TUV-GS, TUV-Mark |
| UES60D1-200300SPC | 45 | 90-264 | 15 | 0.01-3.00 | 0~+40 | CB, CCC, CE, cULus, FCC, NRTL, PSE, RCM, TUV-GS, TUV-Mark |
| UES60D1-200300SPC | 60 | 90-264 | 20 | 0.01-3.00 | 0~+40 | CB, CCC, CE, cULus, FCC, NRTL, PSE, RCM, TUV-GS, TUV-Mark |
The UES60D1-200300SPC adopts a compact desktop enclosure with USB Type-C output, providing a flexible external power solution for medical equipment requiring space-saving design and easy system integration.
Dimensions
Weight
88 × 51.5 × 28mm
175g
The UES60D1-200300SPC supports universal AC input from 90VAC to 264VAC, allowing the same adapter platform to be used across different market requirements.
The input design supports 47-63Hz operating frequency and maintains low standby consumption with ≤0.15W no-load power.
Input Voltage Range
Frequency Range
Input Current
Inrush Current (max)
Touch Leakage Current
90-264VAC
47–63Hz
1.3A at 90VAC
100A max at 240VAC cold start
≤100μA at 264VAC
The series is specified for medical equipment environments with defined operating temperature, humidity and altitude conditions.
The adapter can operate at altitudes up to 5,000m and supports storage conditions from -40°C to +80°C.
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Operating Altitude
MTBF
0℃ to 40℃
-40℃ to 80℃
10–90% RH, non-condensing
5% to 90% RH
5,000m
>100,000hrs (Telcordia SR-332 @25℃)
The UES60D1-200300SPC incorporates protection features to improve operating reliability and help protect the connected equipment under abnormal conditions.
For medical equipment designers, built-in protection functions reduce additional circuit requirements and simplify power system integration.
Overload
Over Voltage
Short Circuit
110–180% rated output power, auto recovery
150% max output voltage, input to reset
Trip and restart (hiccup mode)
The UES60D1-200300SPC series is developed for medical equipment applications where electrical safety and patient protection are important design considerations.
The adapter complies with applicable medical safety standards, helping equipment manufacturers meet regulatory requirements during product certification.
IEC60601-1
ANSI/AAMI ES60601-1
EN60601-1
| Item | Standard |
|---|---|
| Safety Agency / Mark | CB |
| Medical Standard | IEC60601-1 |
| Safety Agency / Mark | UL |
| Medical Standard | ANSI/AAMI ES60601-1 |
| Safety Agency / Mark | TÜV-SÜD / Mark |
| Medical Standard | EN60601-1 |
The UES60D1-200300SPC series addresses electromagnetic compatibility requirements for medical equipment integration.
EMC compliance helps reduce interference concerns when the adapter is used together with sensitive electronic systems and healthcare devices.
| Category | Test Item | Medical | ITE |
|---|---|---|---|
| Emission | Conduction | IEC/EN60601-1-2, CISPR 11 | EN55032, CISPR 32 |
| Emission | Radiation | IEC/EN60601-1-2, CISPR 11 | EN55032, CISPR 32 |
| Emission | Harmonic Currents | EN61000-3-2, Class A | EN61000-3-2, Class A |
| Emission | Voltage Flicker | EN61000-3-3 | EN61000-3-3 |
| Immunity | ESD | IEC61000-4-2 ±15kV air, ±8kV contact | — |
| Immunity | Radiated Immunity | IEC61000-4-3 10V/m, 80MHz-2.7GHz | — |
| Immunity | EFT/Burst | IEC61000-4-4 ±2kV on AC port, ±1kV on signal ports | — |
| Immunity | Surge | IEC61000-4-5 ±2kV line to line, ±4kV line to GND | — |
| Immunity | Conducted Immunity | IEC61000-4-6 3Vrms, 6Vrms (0.15MHz-80MHz) | — |
| Immunity | Magnetic Field | IEC61000-4-8 30A/m | — |
| Immunity | Dips & Interruptions | IEC61000-4-11 0%, 70%, 0% of UT | — |
The UES60D1-200300SPC series provides a 60W USB-C PD power solution for medical and healthcare equipment requiring reliable external power, flexible voltage options and medical-grade isolation.
The compact desktop form factor and USB-C interface make it suitable for equipment where space, power compatibility and patient protection requirements need to be considered during system design.
When selecting an external power adapter for medical equipment, engineers usually need to consider more than just output power. Voltage compatibility, USB-C PD negotiation, isolation requirements and certification level all affect whether the adapter can be integrated into the final device design.
Below are some common questions related to 60W USB-C medical power adapters and the factors to check before selecting a suitable model.
It depends on the input requirements of the equipment. A higher power adapter does not force the device to draw more power; the connected equipment only takes the current it requires. However, the output voltage, connector type and charging protocol should match the device requirements before replacement.
Yes. The UES60D1-200300SPC supports a 20V/3A USB-C PD output profile, providing up to 60W output for equipment requiring higher input power.
Before replacement, check the required voltage, maximum current, USB-C PD compatibility and medical safety requirements of the equipment. A physically compatible connector does not always mean the adapter will work correctly with the device.
Desktop adapters are often preferred when the equipment requires more stable cable routing, easier installation or a separate external power design. They also provide more flexibility when the power input location is fixed within the equipment system.
USB-C PD requires communication between the adapter and the connected device before selecting a higher voltage profile. Compatible equipment can negotiate the required power level from the available PD profiles supported by the adapter.
The required power depends on the device design and operating conditions. A 60W adapter provides additional power capacity for equipment requiring higher input levels compared with common low-power USB adapters, while maintaining a compact external form factor.
2 x MOPP refers to two means of patient protection in medical electrical equipment systems. For devices used in patient-connected environments, this isolation level helps meet safety requirements during product certification.
This type of 60W USB-C medical adapter is commonly considered for equipment such as oxygen concentrators, sleep apnea monitors, nebulizers, infusion pumps, wearable health monitors and dental equipment where medical-grade power protection is required.
Explore other medical power adapter options with different power levels and form factors. These models provide alternatives for equipment designers comparing output requirements, installation space and USB-C or DC power solutions.
Technical information for engineers working on medical equipment power design, including USB-C PD selection, medical safety requirements and power supply integration considerations.
USB-C PD simplifies power connection for many portable devices, but medical applications require additional considerations beyond standard charging performance. This article discusses the differences between consumer USB-C chargers and medical-grade USB-C power solutions.
Isolation requirements are one of the main considerations when selecting a power supply for medical equipment. This guide covers how 2 x MOPP protection is applied, where it is required, and how it relates to IEC60601-1 medical safety requirements.
Medical equipment certification involves more than checking output voltage and power rating. This article covers key IEC60601-1 considerations, including isolation, leakage current and safety requirements for medical power supply selection.
Our engineering team provides comprehensive support for this power supply series. Whether you need standard models, custom DC output specifications, or specific medical compliance assistance, we ensure your requirements are met with precision and speed.
✔ 2 MOPP & IEC 60601-1 Certification Support
✔ Custom DC Connectors & Cable Options
✔ Free Engineering Samples for Evaluation
✔ Detailed Technical Response within 24h