Medical External Power Supply UES18LCP4-SPA
Home Wall Plug Medical External Power Supply UES18LCP4-SPA 18W Switching Power Supply Home Healthcare Medical Wall Plug AC External Power Adapter 18 W 90~ 264
Meets communication and medical safety certification
Contact current ≤ 100μA
Meets level 6 energy efficiency
Standby power consumption ≤ 0.1W
5V/9V/12V/15V/20V output, up to 33W
Working altitude 5000 meters
Meets PD3.0&QC3.0&QC2.0 fast charging protocols
Optional fixed plug/interchangeable pins


UES33LZ-SPC is a 33W compact and efficient wall-plug medical power adapter 12v that supports 90~264Vac wide voltage input and provides a variety of regulated outputs to meet the needs of diverse devices. It complies with IEC 60601-1 Edition 3.1 and IEC 60601-1-2 Edition 4 standards, and has 2 x MOPP isolation protection to ensure safe use, and class 2 power supply is equipped with a variety of optional AC plugs and DC connectors for global applications. This 12V power supply applies to multifunctional detectors, home nebulizers, sleep apnea machines, portable vital signs detectors, urine analyzers, and electronic physiotherapy devices.
Safety Standards – IEC60601,ES60601,EN60601
Safety Approvals – CB, CE, FCC, TUV-Mark
| Model Number | Power(W) | Input Voltage Range(VDC) | Output Voltage(VDC) | Output Current(A) | Operating Temperature Range(℃) | Safety Standards |
|---|---|---|---|---|---|---|
| UES33LZ-SPC | 15.0 | 80-264 | 5.0 | 0.01-3.00 | 0~+40 | CB, CE, FCC, TUV-Mark |
| UES33LZ-SPC | 27.0 | 80-264 | 9.0 | 0.01-3.00 | 0~+40 | CB, CE, FCC, TUV-Mark |
| UES33LZ-SPC | 30.0 | 80-264 | 12.0 | 0.01-2.50 | 0~+40 | CB, CE, FCC, TUV-Mark |
| UES33LZ-SPC | 33.0 | 80-264 | 15.0 | 0.01-2.20 | 0~+40 | CB, CE, FCC, TUV-Mark |
| UES33LZ-SPC | 33.0 | 80-264 | 20.0 | 0.01-1.65 | 0~+40 | CB, CE, FCC, TUV-Mark |






It's ideal for home-use diagnostic devices, patient monitoring equipment, CPAP machines, and handheld medical instruments.
This adapter supports 5V, 9V, 12V, 15V, and 20V to meet various device requirements.
Yes, it powers portable vital sign monitors, oximeter docking units, and bedside devices.
Absolutely, many compact CPAP/APAP units operate within the 12V–20V range.
Yes, it can be manufactured to meet IEC/EN/UL 60601-1 medical safety standards with 2xMOPP protection.
Yes, USB-C (PD) versions are available for modern medical tablets and diagnostic tools.
Blood pressure monitors, glucose meters, fetal dopplers, and nebulizers are common examples.
Yes, many small-scale physical therapy devices use 9V–15V adapters.
Yes, connector types, polarity, and cable lengths can be customized.
The adapter includes over-voltage, over-current, short-circuit, and over-temperature protection.

Home Wall Plug Medical External Power Supply UES18LCP4-SPA 18W Switching Power Supply Home Healthcare Medical Wall Plug AC External Power Adapter 18 W 90~ 264

Home Medical External Desktop Power Supply UES180DZ-SPA Series 180W AC-DC Desktop Medical External Power Supply 56V Switching Power Adapter 180 W 90 ~ 264 Vac

Home Wall Plug Medical External Power Supply UES36WZ1-SPA 12 Volt DC Plug Adapter Wall Plug Medical External Power Supply For Home Devices 36 W 90~

Why Do Many Medical Devices Fail IEC 60601 Certification Even with an Isolated Power Supply? Many medical device manufacturers assume that using an isolated AC-DC

Growing demand for portable medical devices, AI-assisted diagnostic equipment, laboratory instruments, and USB-C powered healthcare systems is driving the need for higher-power medical adapters that

Thermal Failure Mechanisms, IEC 60601 Risks, and Engineering Solutions Overheating is one of the most common causes of medical power supply failure. In medical devices, excessive

How to Identify, Diagnose, and Reduce EMI Problems in Medical Devices Electromagnetic interference (EMI) is one of the most common and difficult problems in medical

Why Medical Devices Fail EMC Certification and How to Fix It Electromagnetic compatibility (EMC) is one of the most challenging parts of IEC 60601 certification

IEC 60601 Design Challenges, Root Causes, and Engineering Solutions Leakage current is one of the most critical safety parameters in medical electrical equipment design. For
For additional assistance, please complete the form below, and an associate will be in touch with you shortly.